Wire Rope/ Wire Rope
Assemblies Considerations:
When selecting the appropriate
wire rope cable for your wire
rope assemblies or control
product, there are a few factors which need to
be considered?
CONSTRUCTURAL
STRETCH:
All wire rope cables
have spaces between each strand and wire. When a load is
applied, the spaces between the wires are reduced and the
wire rope cable will grow in length. The
amount of the growth is determined by the load applied,
length of the cable and construction of
the cable. MCT cable
assemblies can be proof loaded
(by applying a load of 60% of min. cable
breaking strength to the assembly) to eliminate any
constructional stretch.
ELASTIC STRETCH:
An elongation of the
cable wires when a load is applied. This
can be a significant factor when the yield point of the
wire is surpassed. Please contact Motion Control
Technologies to determine the elastic stretch of
a specific
cable.
MINIMAL BREAKING
STRENGTH:
The minimum
breaking strength of the cable is referred to
as the minimum tensile strength. This is measured in lbs. or
kgs. and should be based on the max working load and safety
factor. The recommended minimum safety factor ration is 10:1
which represents (min. breaking strength TO max working
load)
Other factors to determine when designing the
correct cable for your requirements are CABLE
DIAMETER, CABLE MATERIAL, and
COATING ON THE CABLE
|
|
|
Flexibility
|
Tensile Strength
|
Stretch Resistance
|
Relative Cost
|
Corrosion Resistance
|
|
Highest
|
7x19
|
1x19
|
1x7
|
7x19
|
Coated Stainless Steel
|
|
Medium-High
|
7x7
|
1x7
|
1x19
|
7x7
|
Bare Stainless Steel
|
|
Medium Low
|
1x19
|
7x19
|
7x7
|
1x19
|
Coated Galvanized Steel
|
|
Lowest
|
1x7
|
7x7
|
7x19
|
1x7
|
Galvanized Steel
|
|
|